Battery
BATTERY
(12 V - B9 - B)
(12 V - 4 A)
In case of malfunction check first that the recharge system works properly. To check the battery, remove
it from the vehicle, and proceed as follows; visually check that :
- there are no signs of sulphation (signalled by white colouring of one or more cells);
- the electrolyte level is between the two "MIN" and "MAX" reference notches;
- the container (outer casing) does not leak.
Charge the battery slowly for at least 10 hours. With a densimeter check the electrolyte density at every
cell after recharging. If the density is below 1.26 at any cell or if the off-load voltage is lower than 12V,
the battery surely needs to be replaced.
Speed sensor
Operating voltage: Vdc= 5÷24 V
Maximum voltage applicable: 26 V
Maximum reverse voltage: -16 V
Maximum power consumption: 10 mA
Operating temperature:
-20 °C ÷ +80 °C (-7.6 °F ÷ -112 °F)
Electrical system RX SX 125
ELE SYS - 64

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the APRILIA SX 125 and is the answer not in the manual?

APRILIA SX 125 Specifications

General IconGeneral
Displacement124.2 cc
Cooling SystemLiquid cooled
Fuel SystemElectronic fuel injection
Transmission6-speed
Rear SuspensionMonoshock
Front Tire100/80-17
Rear Tire130/70-17
Compression Ratio12.5:1
StarterElectric
ClutchWet multi-plate
Front Brake Disc300 mm
Rear Brake Disc220 mm
Dry Weight134 kg
Bore x Stroke58 mm x 47 mm
Max Power11 kW (15 HP) @ 10, 000 rpm
Front Suspension41 mm USD fork
Front BrakeSingle 300 mm disc
Rear BrakeSingle disc
Fuel Tank Capacity7 liters
FrameSteel perimeter
Engine TypeSingle-cylinder, 4-stroke

Related product manuals