EasyManuals Logo

Atlas Copco ACTA 4000 User Manual

Atlas Copco ACTA 4000
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #61 background imageLoading...
Page #61 background image
ACTA 4000 User Guide Programming ACTA
9836 4171 01 2008-12 61 (136)
tightening result. Enter a numeric (ms) value.
7 End time
The time ACTA waits after the Cycle Complete level before the
tightening cycle is considered to have ended. This delay time is
necessary for the two-stage strategy and for pulse tools. Enter a
numeric (ms) value manually.
8 Slip torque
The Slip Torque that you program in ACTA is the decrease in torque
that is necessary for ACTA to consider that the highest torque is
reached. As soon as ACTA detects a decrease in torque equal to or
greater than the Slip Torque level, ACTA saves the highest torque
before the decrease.
The torque level that is measured and displayed on ACTA is the
maximum torque achieved before slip torque is reached. In the
example below the highest torque is in point A.
The slip torque parameter is only visible and used when
Prog>Measure setup>Measure strat is set to Break away.
When all parameters have been set according to your preference, highlight OK and
press (enter) or simply press the OK button on the keypad.
4.7.5 Statistical setup
In this menu, the statistical setup is made. For more information, see section Guide to statistics.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco ACTA 4000 and is the answer not in the manual?

Atlas Copco ACTA 4000 Specifications

General IconGeneral
BrandAtlas Copco
ModelACTA 4000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals