User's Manual 43. Configuration Parameters Reference
Parameter Description
123456789. In addition, a lifetime of 28800 seconds is selected for IKE
and a lifetime of 3600 seconds is selected for IPSec.
Note: For a detailed description of this table, see 'Configuring IP Security
Associations Table' on page 138.
IPSec Proposal Table
Web: IP Security
Proposal Table
EMS: IPSec Proposal
Table
[IPSecProposalTable]
This table parameter defines up to four IKE proposal settings, where each
proposal defines an encryption algorithm, an authentication algorithm,
and a Diffie-Hellman group identifier.
[ IPsecProposalTable ]
FORMAT IPsecProposalTable_Index =
IPsecProposalTable_EncryptionAlgorithm,
IPsecProposalTable_AuthenticationAlgorithm,
IPsecProposalTable_DHGroup;
[ \IPsecProposalTable ]
For example:
IPsecProposalTable 0 = 3, 2, 1;
IPsecProposalTable 1 = 2, 2, 1;
In the example above, two proposals are defined:
ï‚§ Proposal 0: AES, SHA1, DH group 2
ï‚§ Proposal 1: 3DES, SHA1, DH group 2
Note: For a detailed description of this table, see 'Configuring IP Security
Proposal Table' on page 136.
43.4.7 OCSP Parameters
The Online Certificate Status Protocol (OCSP) parameters are described in the table
below.
Table 43-26: OCSP Parameters
Parameter Description
Web: Enable OCSP Server
EMS: OCSP Enable
[OCSPEnable]
Enables or disables certificate checking using OCSP.
ï‚§ [0] Disable (default)
ï‚§ [1] Enable
For a description of OCSP, refer to the Product Reference Manual.
Web: Primary Server IP
EMS: OCSP Server IP
[OCSPServerIP]
Defines the IP address of the OCSP server.
The default IP address is 0.0.0.0.
Web: Secondary Server IP
[OCSPSecondaryServerIP]
Defines the IP address (in dotted-decimal notation) of the secondary
OCSP server (optional).
The default IP address is 0.0.0.0.
Web: Server Port
EMS: OCSP Server Port
[OCSPServerPort]
Defines the OCSP server's TCP port number.
The default port number is 2560.
Web: Default Response
When Server Unreachable
EMS: OCSP Default
Response
Determines the default OCSP behavior when the server cannot be
contacted.
ï‚§ [0] Disable = (Default) Rejects peer certificate.

Table of Contents

Other manuals for AudioCodes MediaPack Series MP-11x

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack Series MP-11x and is the answer not in the manual?

AudioCodes MediaPack Series MP-11x Specifications

General IconGeneral
BrandAudioCodes
ModelMediaPack Series MP-11x
CategoryGateway
LanguageEnglish

Related product manuals