EasyManuals Logo
Home>AudioCodes>Gateway>MediaPack Series MP-11x

AudioCodes MediaPack Series MP-11x User Manual

AudioCodes MediaPack Series MP-11x
622 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #567 background imageLoading...
Page #567 background image
Version 6.6 567 MP-11x & MP-124
User's Manual 43. Configuration Parameters Reference
Parameter Description
ï‚§
Below configuration forwards calls originally destined to Port 1 to
"1001" upon On Busy:
FwdInfo 0 = 1,1001,30;
ï‚§ Below configuration forwards calls originally destined to Port 2 to an
IP address upon On Busy:
FwdInfo 1 = 1,2003@10.5.1.1,30;
Note: For a detailed description of this table, see Configuring Call
Forward on page 270.
Call Forward Reminder Ring Parameters
Notes:
ï‚§ These parameters are applicable only to FXS interfaces.
ï‚§ For a description of this feature, see Call Forward Reminder Ring on page 249.
Web/EMS: Enable NRT
Subscription
[EnableNRTSubscription]
Enables endpoint subscription for Ring reminder event notification
feature.
ï‚§ [0] Disable (default)
ï‚§ [1] Enable
Web: AS Subscribe
IPGroupID
[ASSubscribeIPGroupID]
Defines the IP Group ID that contains the Application server for
Subscription.
The valid value range is 1 to 8. The default is -1 (i.e., not configured).
Web: NRT Retry
Subscription Time
EMS: NRT Subscription
Retry Time
[NRTSubscribeRetryTime]
Defines the Retry period (in seconds) for Dialog subscription if a
previous request failed.
The valid value range is 10 to 7200. The default is 120.
Web/EMS: Call Forward
Ring Tone ID
[CallForwardRingToneID]
Defines the ringing tone type played when call forward notification is
accepted.
The valid value range is 1 to 5. The default is 1.
43.10.5.4 Message Waiting Indication Parameters
The message waiting indication (MWI) parameters are described in the table below.
Table 43-42: MWI Parameters
Parameter Description
Web: Enable MWI
EMS: MWI Enable
[EnableMWI]
Enables Message Waiting Indication (MWI).
ï‚§ [0] Disable (default).
ï‚§ [1] Enable
Notes:
ï‚§ This parameter is applicable only to FXS interfaces.
ï‚§ The device supports only the receipt of SIP MWI NOTIFY
messages (the device doesn't generate these messages).
ï‚§ For more information on MWI, see 'Message Waiting
Indication' on page 251.

Table of Contents

Other manuals for AudioCodes MediaPack Series MP-11x

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack Series MP-11x and is the answer not in the manual?

AudioCodes MediaPack Series MP-11x Specifications

General IconGeneral
BrandAudioCodes
ModelMediaPack Series MP-11x
CategoryGateway
LanguageEnglish

Related product manuals