EasyManuals Logo

Ecolab EcoAdd User Manual

Ecolab EcoAdd
204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #68 background imageLoading...
Page #68 background image
Type 00510x:
Metering
mode Display
Metering
output
100 %
(V)
Max. stroke
frequency
at 100%
(¦)
Stroke
volume
(V
h
)
Suction
stroke
Duration
(S
t
)
min. metering
stroke
duration
(P
t
)
Standard
5 l/h 155 / min
0,53 l/h
190 ms
197 ms
Medium 4,17 l/h 141 / min 228 ms
Low 3,33 l/h 111 / min 342 ms
Variable
2,5 - 5 l/h 104 - 155 / min 380 - 190 ms
Type 01110S:
Metering
mode Display
Metering
output
100 %
(V)
Max. stroke
frequency
at 100%
(¦)
Stroke
volume
(V
h
)
Suction
stroke
Duration
(S
t
)
min. metering
stroke
duration
(P
t
)
Standard 11,0 l/h 176 / min
1,1 l/h
170 ms
171 ms
Medium
9,66 l/h 160 / min 204 ms
Low 7.73 l/h 126 / min 306 ms
Variable 5.8 - 11.0 l/h 117 - 176 / min 340 - 170 ms
Type 03003S:
Metering
mode Display
Metering
output
100 %
(V)
Max. stroke
frequency
at 100%
(¦)
Stroke
volume
(V
h
)
Suction
stroke
Duration
(S
t
)
min. metering
stroke
duration
(P
t
)
Standard 30 l/h 155 / min
3,4 ml
190 ms
197 ms
Medium 25 l/h 141 / min 228 ms
Low
20 l/h 111 / min 342 ms
Variable 15 - 30 l/h 104 - 155 / min 380 - 190 ms
Control / software
68Rev. 2-05.2018

Table of Contents

Other manuals for Ecolab EcoAdd

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ecolab EcoAdd and is the answer not in the manual?

Ecolab EcoAdd Specifications

General IconGeneral
BrandEcolab
ModelEcoAdd
CategoryWater Pump
LanguageEnglish

Related product manuals