ARM Auto Recovery Module (Optional)
The Auto Recovery Module (ARM) is an optional memory module that is installed between the node and the valve
adapter module and is used to preserve the manifold system parameters even during catastrophic failure. During
the power-up process it reads the configuration of the manifold, including any user settable parameters of I/O
modules, and stores the information in its non-volatile memory. Once the information is stored, it automatically
disconnects itself from the power circuits while still mechanically attached to the manifold.
Description
Replacement Part Number
ARM Module (Legacy) 240-182
ARM-Clip Module
240-383
ARM Module (Legacy)
ARM-Clip Module