User Manual Section 5
GFK-2958L May 2021
Detailed Description of I/O Modules 155
5.4.4 Process Data Inputs EP-1804
Byte
Bit
Description
IB0
IX0.0
DI0
IX0.1
DI1
IX0.2
DI2
IX0.3
DI3
IX0.4
Reserved
IX0.5
Reserved
IX0.6
Reserved
IX0.7
Reserved
5.5 Digital Input Module EP-125F
Figure 64: Digital Input
Module EP-125F
Figure 65: Connection Diagram EP-125F
The EP-125F digital input module can detect up to 16 input signals. Four sensors can be
connected to each connector in a 1-wire connection. A status LED is assigned to each
channel. The connected sensors must be supplied with power from the input current path
IIN (e.g. with potential distribution modules).