00-0

Passed

Normal
01-0

Passed

Normal
02-0

Passed

Normal
03-0

Passed

Normal
 
XSCF>
XSCF>

showhardconf

-M
SPARC

M10-1;

+

Serial:21xxxxxxxx;

Operator_Panel_Switch:Service;

+

System_Power:Off;

System_Phase:Cabinet

Power

Off;

Partition#0

PPAR_Status:Powered

Off;

MBU

Status:Normal;

Ver:2209h;

Serial:TZ01348006

;

+

FRU-Part-Number:CA07363-D011

A0

/7088702

;

+

Power_Supply_System:

;

+

Memory_Size:1024

GB;

Type:

B

;

(*1)

CPU#0

Status:Normal;

Ver:4141h;

Serial:00010263;

+

Freq:3.200

GHz;

Type:0x20;

(*2)

+

Core:16;

Strand:2;

(*3)

MEM#00A

Status:Normal;

+

Code:ce8001M386B8G70BO0-YH94

0000-2151EFEB;

+

Type:47;

Size:64

GB;

MEM#01A

Status:Normal;

+

Code:ce8001M386B8G70BO0-YH94

0000-2151EF8A;

+

Type:47;

Size:64

GB;

 

Omitted
2.
Check
the
execution
results
of
"probe-scsi-all"
to
confirm
that
all
mounted
internal
disks
are
identified.
3.
Check
the
execution
results
of
"show-devs"
to
confirm
that
all
mounted
PCIe
cards
are
identified.
4.
Confirm
that
"Passed"
and
"Normal"
appear
for
all
PSBs
in
the
results
from
the
initial
diagnosis
.
If
the
results
display
anything
other
than
the
above,
see
"Appendix
A
Troubleshooting."
6.8 Checking
the
Component
Status
This
section
describes
the
procedure
for
checking
the
configuration,
status,
and
quantities
of
the
mounted
field
replaceable
units
(FRUs).
1.
Execute
the
show hardconf
command.
The
command
displays
all
the
FRUs
mounted
in
the
chassis
and
their
status.
However,
it
does
not
display
the
status
of
I/O-related
components
such
as
PCI
cards
and
PCI
expansion
units
while
the
system
power
is
off.
Example:
SPARC
M10-1
display
example
Chapter
6
 
Performing
an
Initial
System
Diagnosis 189