EasyManuals Logo
Home>Fujitsu>Server>M10

Fujitsu M10 User Manual

Fujitsu M10
374 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #285 background imageLoading...
Page #285 background image
17.
Perform
an
initial
setup
of
the
instal led
chassis.
For
details,
see
the
following.
-
"7.6
Configuring
Memory
Mirroring"
-
"7.7
Creating
a
Physical
Partition
Configuration
List
(PCL)"
-
"7.8
Assigning
a
System
Board
(PSB)
to
a
Physical
Partition
(PPAR)"
-
"7.11
Registering
a
CPU
Activation
Key"
-
"7.12
Assigning
CPU
Core
Resources"
18.
Reconfigure
the
logical
domains.
Assign
the
resources
of
the
installed
SPARC
M10-4S
to
an
existing
logical
domain
or
a
newly
configured
logical
domain.
For
details,
see
the
Fujitsu
M10/SPARC
M10
Systems
Domain
Configuration
Guide.
9.5 Adding
Expansion
Racks
1
and
2
This
section
describes
the
procedure
for
adding
expansion
racks
1
and
2
and
changing
the
connection
configuration
from
direct
connections
between
chassis
to
connections
through
crossbar
boxes
(the
9BB
configuration
to
the
16BB
configuration).
This
procedure
corresponds
to
pattern
C
in
Figure
8-2.
9.5.1 Changing
a
multiple-BB
configuration
into
1BB
configurations
and
releasing
their
connections
Remove
the
SPARC
M10-4S
from
the
existing
multiple-BB
configuration
(direct
connections
between
chassis),
change
it
to
1BB
configurations,
and
release
their
connections.
To
move
the
SPARC
M10-4S
to
an
expansion
rack,
stop
the
entire
system
and
then
perform
the
work.
Note
the
following
points
on
this
work.
â– 
All
the
system
setting
information
will
be
cleared
and
reset
to
the
factory
defaults.
Before
removing
the
SPARC
M10-4S,
save
the
system
setting
information
with
the
dumpconfig
command.
In
case
of
resetting
the
configuration
to
the
original
setting,
you
can
restore
the
saved
setting
information
to
XSCF
by
using
the
restoreconfig
command.
â– 
Multiple
SPARC
M10-4S
units
cannot
be
released
from
the
system
by
using
the
initbb
command
at
the
same
time.
â– 
The
serial
number
of
the
chassis
of
either
the
master
XSCF
or
standby
XSCF
is
used
as
the
system
serial
number.
If
the
serial
number
of
the
standby
chassis
is
being
used
as
the
system
serial
number,
the
initbb
command
cannot
release
the
standby
chassis.
In
this
case,
execute
the
switchscf
command
to
switch
the
master
XSCF.
Chapter
9
 
Installing
a
System
with
a
Building
Block
Configuration 271

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals