Table
A-1
  
List
of
problem
case
examples
(continued)
Case Possible
cause Corrective
action
After
the
input
power
is
turned
on,
the
MASTER
LEDs
on
all
chassis
are
lit.
BB-IDs
have
not
been
set. Initialize
each
chassis
to
the
factory
default
settings,
and
change
the
BB-IDs
to
the
correct
settings.
See
"A.3.1
BB-IDs
not
set
(BB-ID
00)."
The
XCP
version
check
displays
only
BB#00.
BB-IDs
have
not
been
set. Initialize
each
chassis
to
the
factory
default
settings,
and
change
the
BB-IDs
to
the
correct
settings.
See
"A.3.1
BB-IDs
not
set
(BB-ID
00)."
The
XCP
version
check
displays
only
BB#00
and
BB#01
even
though
the
configuration
has
at
least
three
BBs.
The
BB-IDs
of
BB#00
and
BB#01
are
reversed.
Initialize
BB#00
and
BB#01
to
the
factory
default
settings,
and
change
the
BB-IDs
to
the
correct
settings.
See
"A.3.3
Mistaken
settings
for
BB#00
and
BB#01."
The
XCP
version
check
does
not
display
BB#03
even
though
the
configuration
has
four
BBs.
BB#03
has
the
wrong
BB-ID
setting. Change
the
BB-ID
to
the
correct
setting.
See
"A.3.2
Mistaken
setting
of
a
BB-ID
other
than
BB#00
or
BB#01."
The
component
status
check
(by
the
showhardconf
command)
of
a
building
block
configuration
displays
only
BB#00.
The
XSCF
cables
between
chassis
are
incorrectly
connected.
Check
messages
by
using
the
showlogs
command.
See
"A.2.2
Checking
the
contents
of
logs."
"Failed"
appears
in
the
results
of
a
diagnosis
test
performed
on
a
building
block
configuration.
The
crossbar
cables
between
chassis
are
incorrectly
connected.
Check
messages
by
using
the
showlogs
command.
See
"A.2.2
Checking
the
contents
of
logs."
A.2 Understanding
Commands
for
Troubleshooting
This
section
describes
the
XSCF
shell
commands
used
to
check
detailed
error
information
and
the
system
status.
A.2.1 Checking
the
component
status
Use
the
showhardconf
command
to
check
the
status
of
each
field
replaceable
unit
(FRU).
The
displayed
information
is
as
follows:
â– 
Current
configuration
and
status
Fujitsu
M10/SPARC
M10
Systems
Installation
Guide
ï½¥
July
2015298

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals