EasyManuals Logo
Home>Fujitsu>Server>M10

Fujitsu M10 User Manual

Fujitsu M10
374 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #288 background imageLoading...
Page #288 background image
For
the
procedure
for
mounting
in
the
rack,
see
"3.4.2
Mounting
the
SPARC
M10-4/SPARC
M10-4S
in
a
rack."
9.5.2 Performing
the
work
of
installing
the
expansion
racks
This
section
describes
the
procedure
for
connecting
power
cords
to
the
power
distribution
units
(PDUs)
of
expansion
racks
1
and
2,
and
then
connecting
and
installing
the
racks.
1.
Confirm
the
delivered
components
of
expansion
rack
1
and
expansion
rack
2.
For
details,
see
"3.2.5
Confirming
the
delivered
components
of
an
expansion
rack."
2.
Before
installing
the
rack,
connect
the
power
cords
to
a
power
distribution
unit
(PDU)
of
the
rack.
For
details,
see
"3.3.1
Connecting
the
power
cords
to
the
power
distribution
units
of
an
expansion
rack."
3.
Connect
expansion
racks
1
and
2.
For
details,
see
"3.3.3
Connecting
racks."
9.5.3 Installing
the
SPARC
M10-4S
in
the
expansion
racks
In
the
expansion
racks
installed
in
9.5.2,
mount
the
SPARC
M10-4S
that
was
changed
to
1BB
configurations
in
9.5.1.
Then,
perform
installation
work.
1.
Mount
the
SPARC
M10-4S
in
the
rack.
For
details,
see
"3.4.2
Mounting
the
SPARC
M10-4/SPARC
M10-4S
in
a
rack."
2.
Set
the
ID
required
for
identifying
each
chassis
(BB-ID).
For
details,
see
"4.1
Setting
the
ID
(BB-ID)
Identifying
a
Chassis."
3.
Connect
the
cros sbar
cables
and
XSCF
BB
control
cables
to
each
chassis.
Crossbar
cables
(optical)
and
XSCF
BB
control
cables
are
already
laid
in
the
expansion
rack.
The
work
here
is
to
connect
the
cables
to
each
port
of
the
mounted
chassis.
Connect
the
cables
according
to
the
instructions
written
on
the
labels.
For
details
on
the
connection
of
the
cables
that
pass
between
the
racks,
see
"4.3.2
Connecting
crossbar
cables"
and
"4.3.3
Connecting
XSCF
cables."
For
a
cable
connection
diagram
and
a
cable
list,
see
"
B.5
9BB
Configuration
to
16BB
Configuration
(Connections
through
Crossbar
Boxes)."
4.
Connect
serial
cables,
LAN
cables,
and
power
cords
to
cross bar
boxes.
For
details,
see
"5.4
Connecting
Cables
to
a
Crossbar
Box."
5.
Connect
the
system
management
terminal
to
the
cross bar
box
of
the
mast er
XSCF,
and
then
perform
an
initial
diagnosis
of
the
system.
Fujitsu
M10/SPARC
M10
Systems
Installation
Guide
ï½¥
July
2015274

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals