UTILITIES
Add a Test Code I.D. Prefix to All Symbologies
This selection allows you to turn on transmission of a Code I.D. before the decoded
symbology. (See the Symbology Charts, beginning on page 221 for the single char-
acter code that identifies each symbology.) This action first clears all current pre-
fixes, then programs a Code I.D. prefix for all symbologies. This is a temporary
setting that is removed when the unit is power cycled.
Show Software Revision
Scan the bar code below to output the current software revision, unit serial number,
and other product information for the 8680i.
Test Menu
When you scan the Test Menu On code, then scan a programming code in this
manual, the 8680i displays the content of a programming code. The programming
function still occurs, but in addition, the content of that programming code is out-
put to the terminal.
Note: This feature should not be used during normal 8680i operation.
Add Code I.D. Prefix to
All Symbologies (Temporary)
Show Software Revision

Table of Contents

Other manuals for Honeywell 8680i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell 8680i and is the answer not in the manual?

Honeywell 8680i Specifications

General IconGeneral
TypeWearable bar code reader
Sensor type-
Scanner type1D/2D
Pitch reading angle-45 - 45 °
Motion tolerance (cm/s)584
Light levels (direct sunlight)0 - 100000 lx
Linear (1D) barcodes supportedCode 39, PDF417, U.P.C.
2D (matrix & stacked) barcodes supportedData Matrix, PDF417
Bluetooth version4.1
Standard interfacesBluetooth
Connectivity technologyWireless
Product colorBlack
Built-in displayNo
International Protection (IP) codeIP54
Charging time4 h
Battery voltage3.6 V
Power source typeBattery
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth81 mm
Width56 mm
Weight- g