EasyManuals Logo
Home>HP>Switch>5920

HP 5920 Configuration Guide

HP 5920
322 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #123 background imageLoading...
Page #123 background image
113
Entry Parameters to be compared
Maximum number
of entries
Alarm
• Alarm variable (alarm-variable)
• Sampling interval (sampling-interval)
• Sample type (absolute or delta)
• Rising threshold (threshold-value1)
• Falling threshold (threshold-value2)
60
Private alarm
• Alarm variable formula (prialarm-formula)
• Sampling interval (sampling-interval)
• Sample type (absolute or delta)
• Rising threshold (threshold-value1)
• Falling threshold (threshold-value2)
50
To configure the RMON alarm function:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. (Optional.) Create an
event entry in the event
table.
rmon event entry-number [ description string ] { log |
log-trap security-string | none | trap security-string }
[ owner text ]
By default, the RMON
event table does not
contain entries.
3. Create an entry in the
alarm table or private
alarm table.
• Create an entry in the alarm table:
rmon alarm entry-number alarm-variable
sampling-interval { absolute | delta }
[ startup-alarm { falling | rising | rising-falling } ]
rising-threshold threshold-value1 event-entry1
falling-threshold threshold-value2 event-entry2
[ owner text ]
• Create an entry in the private alarm table:
rmon prialarm entry-number prialarm-formula
prialarm-des sampling-interval { absolute | delta }
[ startup-alarm { falling | rising | rising-falling } ]
rising-threshold threshold-value1 event-entry1
falling-threshold threshold-value2 event-entry2
entrytype { forever | cycle cycle-period } [ owner
text ]
By default, the RMON
alarm table and the
private alarm table do
not contain entries.
You can associate an
alarm with an event
that has not been
created yet. The alarm
will trigger the event
only after the event is
created.
Displaying and maintaining RMON settings
Execute display commands in any view.
Task Command
Display RMON statistics. display rmon statistics [ interface-type interface-number]
Display RMON history control
entries and history samples.
display rmon history [ interface-type interface-number ]
Display RMON alarm entries. display rmon alarm [ entry-number ]