263
</Interface>
<Interface>
<IfIndex>2683</IfIndex>
<Description>Ten-GigabitEthernet1/0/3 Interface</Description>
</Interface>
<Interface>
<IfIndex>2684</IfIndex>
<Description>Ten-GigabitEthernet1/0/4 Interface</Description>
</Interface>
</Interfaces>
</Ifmgr>
</top>
</data>
</rpc-reply>
Example for filtering data by conditional match
Network requirements
Retrieve data in the Name column with the ifindex value not less than 5000 in the Interfaces table under
the Ifmgr module.
Configuration procedure
# Enter XML view.
<Sysname> xml
# Exchange capabilities.
<hello xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<capabilities>
<capability>
urn:ietf:params:netconf:base:1.0
</capability>
</capabilities>
</hello>
# Retrieve data in the Name column with the ifindex value not less than 5000 in the Interfaces table
under the Ifmgr module.
<rpc message-id="100"
xmlns="urn:ietf:params:xml:ns:netconf:base:1.0"
xmlns:nc="http://www.hp.com/netconf/base:1.0">
<get>
<filter type="subtree">
<top xmlns="http://www.hp.com/netconf/data:1.0">
<Ifmgr>
<Interfaces>
<Interface>
<IfIndex nc:match="more:5000"/>
<Name/>
</Interface>
</Interfaces>