A Utilities
SAS disk setup
Using the saupdate command
The saupdate command is used to query or change the mode of the Smart Array P410i and
Smart Array P411 controllers to HBA or RAID. Querying or changing modes is not supported for
other controllers.
The newly added commands to saupdate are:
Get Mode
Set Mode
Get mode
This command displays the current mode of the controllers.
Syntax
saupdate get_mode <controller>
<controller> can be any one of the following strings.
Table 41 <controller> strings
Meaning<controller>
A controller having the PCI segment id, bus id, device id and function id is addressed<seg:bus:dev:func>
Addresses all controllers in the systemall
Controllers of a particular type indicated by the <model> string are addressed<model>
130 Utilities