Table 5: Acousc Noise Measurements for EX4100 and EX4100-F Switch Models
(Connued)
Sound Pressure (Acouscs)
Switch Model Power Supply LpA (dB)
Typical
1PSU/2PSU
Max
1PSU/2PSU
EX4100-48T-AFI 150 AC AFI NA 38.4/38.2
EX4100-48T-DC 150 DC AFO NA 37.5/37.7
EX4100-48P 920W AC AFO 38.7/39.3 46.1/48.2
EX4100-24MP 920W AC AFO 38.9/39.4 46.5/51.1
EX4100-48MP 920W AC AFO 36.8/48.0 45.3/54.3
EX4100-F-24T 65W AC AFO NA 35.4
EX4100-F-24P 450W AC AFO 40.1 45.1
EX4100-F-48T 90W AC AFO NA 37.1
EX4100-F-48P 850 AC AFO 46.2 46.5
Field-Replaceable Units in EX4100 Switches
Field-replaceable units (FRUs) are components that you can replace at your site. The FRUs in EX4100
switches are hot-removable and hot-insertable. You can remove and replace them without powering o
the switch or disrupng switch funcons. The FRUs in EX4100 switches are:
Power supplies.
Fan modules.