EVERY 4000 HOURS MAINTENANCE
METHOD FOR CHANGING OIL IN POWER UNIT
WARNING
• Before
changing the oil of the power unit, always lower the ladder to the lowest position. Otherwise,
the ladder may fall down while draining the oil and hit the person or the ladder may be damaged.
• After operating the power ladder, the parts and oil are very hot and may cause burn injury. Wait for
the temperature to go down, and then start the work.
Refill capacity: 1.8 ℓ
Prepare a container to catch the oil.
1.
Remove the cap (1).
2.
Take the drain hose (2) out of the machine.
3.
Place a container to catch the oil.
4.
Loosen the drain valve (3) and drain the oil.
5.
Refill the power unit with Komatsu genuine power train oil
TO10 through the oil filler port (F).
ATTACHMENTS AND OPTIONS HANDLE HYDRAULIC TYPE LADDER
6-23