PMRA
199
PMRA — in Path, Move to Relative position
specified by Angle
Format
PMRA x-coordinate, y-coordinate, distance, angle;
Parameters
x-coordinate, y-coordinate:
coordinates as measured from the left and top edge limits of the page
distance:
distance specified in increments governed by the unit value.
angle:
angle in degrees, measured counterclockwise from the positive x axis
Function
The PMRA command moves the cursor to a position in a path construction, specified
relative to the left and top edge limits of the page, then across a distance specified
relative to the x- and y-coordinate and at a specified angle.
It should be noted that the x and y coordinates are measured from the top and left edge
limits of the page, and not from the current cursor position.
The coordinates and distance are measured in the units designated by the UNIT
command. The angle is measured counterclockwise from the positive x axis.
New cursor position
Positive x axis
Angle
Distance
(x, y)