Configuration
Code table
8
8.3
8.3-29
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0472 -199.99 {0.01 %} 199.99
Configuration of free control
codes for analog signals
1 FCODE analog 0.00
2 FCODE analog 0.00
3 FCODE analog 100.00
6 FCODE analog 0.00
... ... 0.00
20 FCODE analog 0.00
C0473 -32767 {1} 32767
Configuration of free control
codes for absolute analog signals
1 FCODE ABS 1
2 FCODE ABS 1
3 FCODE ABS 0
... ... 0
10 FCODE ABS 0
C0474 -2147483647 {1} 2147483647
Configuration of free control
codes for phase signals
z 1 rev. = 65536 inc
1 FCODE PH 0
... ... 0
5 FCODE PH 0
C0475 -16000 {1} 16000
Configuration of free control
codes for phase difference signals
z 1 rev. = 65536 inc
1 FCODE DF 0
2 FCODE DF 0
C0497 Nact filter 2.0 0.0 {0.1 ms} 50.0 Filter time constant N
act
for
actual speed value, function
block MCTRL2
z Internal filtering of the speed
signal for control
z C0497=0ms:Switchedoff
8.2-48
C0510
CFG: IN1 50 AIN1-OUT Selection list 1 Configuration of analog input
signal, function block NLIM1
z Input for analog speed
setpoint
See System
Manual
(extension)
C0511 DIS: IN1 -199.99 {0.01 %} 199.99 Function block NLIM1
z Display of the input signal
configured in C0510