Technical data
Operation with rated power (normal operation)
Rated data for 480 V mains voltage
3
3.2
3.2.2
3.2-6
EDSVF9333V EN 3.0-06/2005
Typical motor power
Three-phase asynchronous motor
(4-pol.)
P
r
[kW] 37 55 75 90 110
P
r
[hp] 49.5 74 100 120 148
9300 vector type EVF9329 EVF9330 EVF9331 EVF9332 EVF9333
Mains voltage U
mains
[V] 3/PE AC 320 V - 0 % ... 528 V + 0 % ; 45 Hz - 0 % ... 65 Hz + 0 %
Alternative DC supply U
DC
[V] DC 460 V - 0 % ... 740 V + 0 %
Data for operation on 3/PE AC 480 V or DC 678 V
Rated mains current
Without mains choke/mains filter I
mains
[A] – – – – –
With mains choke/mains filter I
mains
[A] 55.0 80.0 100 135 165
Output power U, V,
W with switching
frequency
2and4kHz
S
N
[kVA] 49.9 69.8 91.4 124 158.2
8kHz
S
N
[kVA] 49.9 69.8 91.4 124 149
Output power +U
DC
,-U
DC
1)
P
DC
[kW] 0.0 5.9 0.0 32.4 47.1
Rated output current
with switching
frequency
2and4kHz I
r
[A] 56.0 84.0 105 142 171
8kHz I
r
[A] 56.0 84.0 105 142 141
8kHzsin I
r
[A] 44.0 55.0 71.0 87.0 94.0
16 kHz I
r
[A] 33.0 43.7 49.5 55.0 59.0
8/2 kHz
3)
I
r
[A] 56.0 84.0 105 142 171
Max. permissible
output current for 60
s at a switching
frequency
2) of
2and4kHz I
max
[A] 84.0 126 157 213 256
8kHz I
max
[A] 84.0 126 157 213 211
8kHzsin I
max
[A] 66.0 82.0 107 130 141
16 kHz I
max
[A] 49.0 65.6 74.0 83.0 89.0
8/2 kHz
3)
I
max
[A] 84.0 126 157 213 256
Output voltage
With mains choke/mains filter U
M
[V] 3~0...approx.94%U
mains
/ 0 ... 600 Hz
Power loss (operation with I
N
) P
v
[W] 810 1100 1470 1960 2400
Required mains choke Type
ELN3-0055H055 ELN3-0038H085 ELN3-0027H105 ELN3-0022H130 ELN3-0017H170
Dimensions
H [mm] 350 510 591 680 680
b [mm] 250 340 340 450 450
T [mm] 250 285 285 285 285
Earth [kg] 18.0 36.0 38.0 70.0 70.0
Bold print = Lenze setting
1)
Power supplied by the DC bus when operating with power-adapted motor
2)
Currents for periodic load change: 60 s of overcurrent time with I
max
and 120 s of base load time
with 75 % I
N
3)
Power-optimised operation with automatic switching frequency reduction. When the max.