Installing the basic device
Basic devices in the power range 15 ... 30 kW
Mounting in ”cold plate” technique
4
4.2
4.2.4
4.2-5
EDSVF9333V EN 3.0-06/2005
d
b1
c
c1
a
a1
g
e
<7C
L
b
9300vec119
Fig. 4.2-3 Dimensions for mounting in ”cold plate” technique 15 ... 22 kW
9300 vector Dimensions [mm]
Type a a1 b b1 c c1 d e
1)
g
EVF9327-CVV003
EVF9328-CVV003
234 250 381 350 110 220 367 171 6.5
1)
For a fieldbus module plugged onto X1, consider mounting space for connecting cables
Apply heat conducting paste before screwing together the cooler and
cooling plate of the drive controller so that the heat transfer resistance is as
low as possible.
1. Clean the contact surface of cooler and cooling plate with spirit.
2. Apply a thin coat of heat conducting paste with a filling knife or brush.
The heat conducting paste i n the accessory kit is sufficient for an area
of approx. 1000 cm
2
.
3. Mount the drive controller on the cooler.
Dimensions