EasyManuals Logo
Home>Lenze>DC Drives>EVF9324

Lenze EVF9324 User Manual

Lenze EVF9324
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #374 background imageLoading...
Page #374 background image
Configuration
Code table
8
8.3
8.3-65
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C1160
Selection list 1 Configuration of analog input
signals, function block ASW3
See System
Manual
(extension)
1 CFG: IN 1000 FIXED0% ASW3-IN1
2 CFG: IN 1000 FIXED0% ASW3-IN2
C1161
CFG: SET 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block ASW3
z LOW: signal at ASW3-IN1 is
output to ASW3-OUT
z HIGH: signal at ASW3-IN2 is
output to ASW3-OUT
C1162 -199.99 {0.01 %} 199.99 Function block ASW3
z Display of the signals linked in
C1060
1 DIS: IN ASW3-IN1
2 DIS: IN ASW3-IN2
C1163 DIS: SET Function block ASW3
z Display of the signal linked in
C1061
C1300
N-motor/Dmax 300 -32767 {1 rpm} 32767 Motor speed at D
max
, function
block DCALC1
z Nominal speed of the winding
drive
8.2-1
C1301
N-line max 3000 1 {1 rpm} 32767 Maximum line speed, function
block DCALC1
z Nominal speed of the line
drive
C1302 calc cycle 0.1 0.1 {0.1 rev} 100.0 Calculation cycle, function block
DCALC1
8.2-1
C1303 time const 0.10 0.01 {0.01 s} 50.00 Filter time constant, function
block DCALC1
C1304
Dmax 500 1 {1 mm} 10000 Maximum diameter, function
block DCALC1
z Nominal winding diameter
8.2-1
C1305 lower D-limit 50 1 {1 mm} 10000 Lower diameter limit, function
block DCALC1
z Minimum winding diameter
C1306 upper D-limit 500 1 {1 mm} 10000 Upper diameter limit, function
block DCALC1
z Maximum winding diameter
C1307 hyst D-limit 1.00 0.00 {0.01 %} 100.0 Hysteresis - diameter limitation,
function block DCALC1
z Hysteresis for D
min
/D
max
output
C1308
arit function 1
0 DCALC1-OUT=D DCALC1-OUT =
diameter
Selection of the arithmetic
function, function block DCALC1
8.2-1
1 DCALC1-OUT=1/D DCALC1-OUT =
1/diameter
C1309
Dmin 50 1 {1 mm} 10000 Minimum diameter, function
block DCALC1
8.2-1
C1310 DCALC1-Titime 0.000 0.000 {0.001
s}
999.900 Acceleration and deceleration
time, function block DCALC1
C1311 window D-calc 1.00 0.00 {0.01 %} 100.00 Window - diameter calculation,
function block DCALC1
z Window setting for
permissible diameter deviation

Table of Contents