Configuration
Code table
8
8.3
8.3-69
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C1375
Selection list 1 Configuration of analog input
signals, function block FOLL1
See System
Manual
(extension)
1 CFG: SIGN 1000 FIXED0% z Negative value: signal
characteristic at FOLL1-OUT is
opposed to the one at
FOLL1-IN
z Positive value: signal
characteristic at FOLL1-OUT is
thesameasatFOLL1-IN
2 CFG: IN 1000 FIXED0% If FOLL1-IN > FOLL1-REF, the ramp
function generator starts
3 CFG: REF 1000 FIXED0% Reference value
4 CFG: LOAD 1000 FIXED0% Initial value for the ramp function
generator
C1376
CFG: SET 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block FOLL1
z HIGH: initial value at
FOLL1-LOAD is accepted
C1377 -199.99 {0.01 %} 199.99
Function block FOLL1
z Display of the signals linked in
C1375
See System
Manual
(extension)
1 DIS: SIGN
2 DIS: IN
3 DIS: REF
4 DIS: LOAD
C1378 DIS: SET 0 1 Function block FOLL1
z Display of the signal linked in
C1376
C1583 fset high 100.00 0.00 {0.01 %} 199.99 Adaptation of the motor
magnetising current set in C0095
(with V/f characteristic control:
influence limit of the boost
correction; with vector control:
influence limit of the field
precontrol)
z The output frequency is set up
to which the motor
magnetising current set in
C0095 is to have an effect.
z C1583 = 100 % half the
rated motor frequency in
C0089
6.11-5
C1751
0 {1} 65535
Inverter compensation
characteristic (WRK)
z During the motor parameter
identification, the
characteristic is calculated
from the measured motor
stator resistance and saved in
C1751/1 ... C1751/17
6.6-13
1 0
... ...
17 0
C1753
0 Data are not o. k.
Internal data are o. k.
z Motor data identification for
the inverter compensation
characteristic has been
completed successfully
1 Data are o. k.
C1754
0 Data are not o. k.
Internal data are o. k.
z Motor data identification for
the motor leakage inductance
has been completed
successfully
1 Data are o. k.
C1755
100 0 {1} 65535 Image of inverter compensation
characteristic (WRK) on the
maximum current range