EasyManuals Logo
Home>Motorola>Two-Way Radio>APX 3000

Motorola APX 3000 Detailed Service Manual

Motorola APX 3000
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
Troubleshooting Charts: DC Supply Failure 5-15
5.4 DC Supply Failure
5.4.1 DC Supply 5 Volt Failure
V_SW_5
Is fuse intact
(not blown)?
Replace Fuse
Verify UNSW_B+ at
test point: F_UNSW_B+
Verify if USB accessory is
shorting VBUS line.
Verify L200, C202
and C203 is good
Replace accessory
or cable
Verify SW_B+
at C6565
Check Q6502 and
Q6508 for damage
Is 6 < V < 9
Verify Q6501
Measure BGAP_COMP
voltage at R6543
Is 2.2 < V < 2.7
Check U6505 circuitry. If good,
change U6505
Check BGAP_COMP circuitry.
Replace defective part
Is radio current
>100mA
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No

Table of Contents