Output specifications The specifications for the interlock status opto-isolator outputs are as
follows:
Output Format: open collector, open emitter transistor
Maximum Voltage: 26 V DC
Minimum Guaranteed Output Current Drive: 20 mA (30 mA
typical) @ 1.0 V max
Jumper X5 Jumper setting X5 selects the source for interlock status output. The
following jumper settings select the indicated interlock source:
X5 Jumpered = HSM Board Interlocks Only
X5 Not Jumpered = Station and HPU Interlocks
Jumpers W8/W9 Jumper settings W8/W9 determine the output polarity of the opto-
isolators.
Cable specification 9-contact type D female EMI connector
Backshell–EMI metallized plastic
Cable–shielded twisted pairs (24 AWG minimum) with drain
wire(s) connected to the metallized backshell at the chassis.
J49 Auxiliary Power
Connector J49 Aux Pwr provides +5 V DC, ±15 V DC, and 24 V DC
from the chassis internal power supply to drive external high level
conditioners, proximity switches, solenoids, and so forth.
The outputs are fused at 0.75 A to protect the power supply from
an external short.
The fuses can be reset by shutting off power and waiting a few
minutes (the fuses automatically reset when cooled) then
reapplying power.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Systems FlexTest IIm and is the answer not in the manual?

MTS Systems FlexTest IIm Specifications

General IconGeneral
BrandMTS Systems
ModelFlexTest IIm
CategoryController
LanguageEnglish

Related product manuals