MTS 793 Controller Hardware FlexTest GT Controller Connections
159
J52 Box Out
The J52 Box Out connector provides an interface for connecting
multiple MTS controller boxes together to allow sharing of station
interlock status and a master synchronization clock.
Last controller jumper The last controller box in a chain must have a jumper plug (MTS PN
100-079-126) on its J52 Box Out connector. This jumper allows the
return of the composite station interlock signal for all controllers in the
chain to monitor.
Note If there is only one controller, a jumper is still required on its Box
Out connector.
Cable specification Use MTS cable PN 056-534-1xx.
+clk in
/intlk out 2
/intlk out 1
/intlk out 3
/intlk out 4
test
-clk out
/intlk return in 1
/intlk return in 2
/intlk return in 3
/intlk return in 4
signal return
signal return
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
J52 Box Out
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Systems FlexTest IIm and is the answer not in the manual?

MTS Systems FlexTest IIm Specifications

General IconGeneral
BrandMTS Systems
ModelFlexTest IIm
CategoryController
LanguageEnglish

Related product manuals