MTS 793 Controller Hardware
FlexTest GT Controller Connections
140
Connecting Interlock Signals to 407 Controllers
The Model 793 Controller monitors digital I/O interlock signals through
the Model 493.74 HSM transition module’s J43A and J43B connectors.
Use these connectors when connecting to Model 407 Controllers.
Model 493.74 HSM transition module connectors are as shown in the
figure that follows.
Interlock cabling to Model 407 Controllers depends on your system’s
configuration. There are three possible configurations:
Single station—one Model 407 Controller runs a single test
program.
Multiple stations—two or more independent Model 407
Controllers each run different test programs.
Master-dependent station—one master Model 407 Controller
daisy-chained with other dependent Model 407 Controllers
together run a single test program.