Chapter 4 HOST INTERFACE
92
For example, if the printer is printing a job from the serial port, and
then receives a second print job from the parallel port, the data from
the parallel port will “trickle” bit by bit into the printer buffer to
prevent a timeout error from being sent back to the host connected
to the parallel port.
The selected value is the time that the printer waits before getting
the next byte of data from the host. The Trickle Time value should
be less than the host time out value, but not too much shorter or
else the printer fills up its buffer too fast. This function is not
applicable for C/T hotport.
Dataproducts (Standard) Submenu
Dataproducts
(from page 83)
Data Bit 8
PI Ignored Data
Polarity
Resp.
Polarity
Latch Data
On
Prime Signal
TOF Action
Buffer Size
in K
Enable*
Disable
Enable*
Disable
Standard*
Inverted
Standard*
Inverted
Middle*
Trailing
Leading
Disable*
Enable
Reset*
Do Nothing
16*
(1-16)
* = Factory Default
Auto
Trickle
Disable*
Enable
Trickle
Time
1/4 sec*
1/2 sec
1 sec
2 sec
4 sec
8 sec
16 sec
Off

Table of Contents

Other manuals for Oki MICROLINE MX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oki MICROLINE MX Series and is the answer not in the manual?

Oki MICROLINE MX Series Specifications

General IconGeneral
BrandOki
ModelMICROLINE MX Series
CategoryPrinter
LanguageEnglish

Related product manuals