8 - 9
8 Pulse Output Units
NX-series Position Interface Units User’s Manual (W524)
8-4 Basic Application Procedures
8
8-4-1 Procedures When Using the Motion Control Function Module
8-4 Basic Application Procedures
This section describes the basic procedures to use a Pulse Output Unit.
The procedure depends on whether the MC Function Module is used.
The process flow to use a Pulse Output Unit with the MC Function Module is shown below.
8-4-1 Procedures When Using the Motion Control Function Module
START
A
Continues to on the following page.
Create a project.
Create the EtherCAT network configuration.
Create the NX Unit configuration.
Set the NX Unit parameters.
Add axes.
Assign the axes.
Set the axis parameters.
Set up the functions in the MC Function Module.
Set the Controller Setup.
Transfer the project to the Controller.
Open the MC Test Run Tab Page.
Monitor input signals to check the wiring.
Perform jogging.
Write a program to perform jogging.
Jog the axes with the user program.
*1
Define the homes of the servomotor axes to control.
*1
*1
*1
Setup
Transferring
Axis Settings
Checking Wiring
Programming
Homing
Checking Operation
Manual Operation