3 Part Names and Functions
3 - 2
NX-series Position Interface Units User’s Manual (W524)
3-1 Parts and Names
This section describes the names and functions of the parts of the Position Interface Units.
NX-EC0112, NX-EC0122, NX-EC0212, NX-EC0222, NX-ECS112, NX-ECS212,
NX-PG0112, and NX-PG0122
NX-EC0132 and NX-EC0142
Letter Name Function
(A) Marker attachment locations This is where the markers are attached. OMRON markers are pre-installed at
the factory. You can also install commercially available markers.
(B) NX bus connector This connector is used to connect to another Unit.
(C) Unit hookup guides These guides are used to connect two Units to each other.
(D) DIN Track mounting hooks These hooks are used to mount the NX Unit to a DIN Track.
(E) Protrusions for removing the Unit These protrusions are to hold onto when you need to pull out the Unit.
(F) Indicators The indicators show the current operating status of the Unit.
(G) Terminal block The terminal block is used to connect to external devices.
The number of terminals depends on the Unit.
(H) Unit specifications The specifications of the Unit are given here.
(C)(D)
(H)
(G)
(F)
(C)
(A)
(E)
(C)(E)
(C)
(B)
(B)
(B)
(A)
(C)(C) (E)
(D)
(B)
(H)
(G)
(F)
(C)(E)
(C)