PG-FP5 APPENDIX A MESSAGES
R20UT0008EJ0400 Rev. 4.00 Page 210 of 240
Jul 15, 2010
(2/3)
No. Message Description
I 2211 Updating the FPGA will take several minutes.
ATTENTION:
-The process of updating your FPGA must NOT be
interrupted!
-Without FPGA this FP5 GUI will NOT run properly.
Install new FPGA in your programmer?
The FPGA update will take several minutes.
ATTENTION:
The FP5 may not operate normally if a proper FPGA is not
installed.
Select whether to update the FPGA.
I 2212 You must be careful before start Self-test.
ATTENTION:
-Remove any plugs from Target- and
Remote-connector before starting.
-Any hardware attached to those connectors may be
damaged by this test!
Start Self-test?
Note the following points before performing self-testing.
ATTENTION:
Unplug all target connectors and remote connectors.
If any hardware is connected, it may be damaged by this
testing.
I 2213 Project folder and parameter file is not defined.
Click button [Yes] if create the setting file newly
Click button [No] if select the existing setting file
−
I 2214 Parameter setting file is not defined.
use most recent setting as default
−
I 2215 Selected parameter files are copied to specified project
folder.
User selected parameter files are copied to the destination.
I 2216 <Parameter file name> already exists. Do you want
overwrites the existing file?
−
I 2300 Value out of range. The set value is out of the valid ranges. The valid code
flash range is 0-0x400000. The valid data flash range is
0x400000 to 0x420000.
I 2302 Please give file range Input the file range. No arguments are specified for the
range.
I 2401 Caution: When 'Chip Erase' is disabled, chip cannot be
erased and programmed any more!
If Chip Erase is disabled, the flash memory in the target
device cannot be erased or rewritten.
I 2402 Caution: When 'Boot block cluster reprogramming' is
disabled, chip cannot be erased and programmed any
more!
If Boot block cluster reprogramming is disabled, the flash
memory in the target device cannot be erased or rewritten.
I 2411 The selection is out of range. The selected communication speed is higher than the
maximum value defined in the PR5 file.
I 2412 The selection is out of range. The selected communication speed is lower than the
minimum value defined in the PR5 file.
I 2413 Value is out of range. The selected clock value is larger than the maximum value
defined in the PR5 file.
I 2414 Value is out of range. The selected clock value is smaller than the minimum value
defined in the PR5 file.
I 2415 The selection is out of range. The VDD value exceeds the range defined in the PR5 file.