PG-FP5 APPENDIX A MESSAGES
R20UT0008EJ0400 Rev. 4.00 Page 213 of 240
Jul 15, 2010
(2/3)
No. Message Error Condition Possible Workaround
050 Bln Timeout Blank check timed out
A communication problem occurred between the FP5 and
target device. Try the operation again.
051 Blank chk failed Blank check failed
The device connected is not empty. Use the ‘erase’
command before programming.
060 Wrb Timeout Writeback timed out
There was a communication problem between the FP5 and
target device. Try the operation again.
061 Writeback failed Writeback failed A device defect is most probably causing this error.
062 Wrb retry exceed Writeback retry timed out A device defect is most probably causing this error.
063 Wrb Timeset err Writeback time setting error The parameter file may contain invalid data.
Contact Renesas Electronics.
070 Write timeout Write timed out
There was a communication problem between the FP5 and
target device. Try the operation again.
071 Write failed Write operation failed
Either the device was not blank before writing or a device
defect is causing this error.
072 Write retry err Write retry error
Either the device was not blank before writing or a device
defect is causing this error.
073 Wrt. Timeset err Write time setting error
The parameter file may contain invalid data. Contact
Renesas Electronics.
080 Vrf Timeout Verify timed out
There was a communication problem between the FP5 and
target device. Try the operation again.
081 Verify failed Verify failed
The data in the target device’s flash memory is not the
same as in the FP5.
090 IVrf Timeout Internal verify timed out
There was a communication problem between the FP5 and
target device. Try the operation again.
091 IVerify failed Internal verify error
An error was occurred while the write data level was being
checked.
092 VGT Comm err Device communication error
The FP5 is not communicating properly with the target
device. Check that the FP5 is correctly connected to the
target device.
093 SUM Comm err Device communication error
The FP5 is not communicating properly with the target
device. Check that the FP5 is correctly connected to the
target device.
094 SCF Comm err Device communication error
The FP5 is not communicating properly with the target
device. Check that the FP5 is correctly connected to the
target device.
204 Not connected
The target device was not connected
to FP5 when a ‘disconnect’ command
was issued.
210 Already conn.
A connect command was issued when
the target device was already
connected to FP5.
301 Security ID err Security ID does not match. Please specify the Security ID as stored in the device.
<R>

Table of Contents

Other manuals for Renesas PG-FP5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renesas PG-FP5 and is the answer not in the manual?

Renesas PG-FP5 Specifications

General IconGeneral
BrandRenesas
ModelPG-FP5
CategoryMotherboard
LanguageEnglish

Related product manuals