PG-FP5 APPENDIX A MESSAGES
R20UT0008EJ0400 Rev. 4.00 Page 214 of 240
Jul 15, 2010
(3/3)
No. Message Error Condition Possible Workaround
302 HEX range err Program file size error
The address range of the downloaded program file is
outside the address range set in the [Operation Mode] area
on the [Standard] tab of the Device Setup dialog box.
400 Targ. power det. Target power detected! Check Setup.
FP5 should supply V
DD power, but supply voltage has been
detected to be already present on the target board. Please
change Setup (uncheck: V
DD: On Target).
401 FP5 int Vpp fail FP5 Power failure. Please contact Renesas Electronics support desk.
402 FP5 int Vdd fail FP5 Power failure. Please contact Renesas Electronics support desk.
403 FP5 int Vdd2 fail FP5 Power failure. Please contact Renesas Electronics support desk.
404 Targ. power fail
No V
DD applied or Voltage is out of
range.
VDD is supplied from target board, but VDD voltage does not
match the V
DD value in FP5 Setup. Check, if the VDD power
settings are OK.
405 Power failure
A supply voltage failure has been
detected.
There is possibly a shortcut in the target hardware.
590 IDC Comn err
Device communication error or illegal
OCD security ID setting
The FP5 is not communicating properly with the target
device. Check that the FP5 is correctly connected to the
target device. Also check that the on-chip debug security
ID is correct.
591 OPB Comn err
Device communication error or illegal
OCD security ID setting
The FP5 is not communicating properly with the target
device. Check that the FP5 is correctly connected to the
target device. Also check that the on-chip debug security
ID is correct.