RL78/F13, F14 CHAPTER 17 LIN/UART MODULE (RLIN3)
R01UH0368EJ0210 Rev.2.10 1195
Dec 10, 2015
17.3 Modes
The LIN/UART module provides the following four modes, depending upon the specific function to be performed:
 LIN reset mode
 LIN mode
(LIN master mode/LIN slave mode [auto baud rate]/LIN slave mode [fixed baud rate])
 UART mode
 LIN self-test mode
The supply of clocks to the LIN/UART module is stopped in LIN reset mode, which reduces power consumption.
Figure 17-3 shows mode transitions. Table 17-4 describes mode transition conditions. Table 17-5 lists operations available
in each mode.
Figure 17-3. Mode Transitions
CPU reset
LIN reset mode
(5)
(3)
(4)
(6)
(1) (2)
UART mode
- LIN master mode
- LIN slave mode
[Auto baud rate]
- LIN slave mode
[Fixed baud rate]
LIN modes
LIN self-test mode