RL78/F13, F14 CHAPTER 34 ELECTRICAL SPECIFICATIONS (GRADE L)
R01UH0368EJ0210 Rev.2.10 1720
Dec 10, 2015
34.5.3 On-chip Debug (UART)
(TA = -40 to +105ï‚°C, 2.7 V ï‚£ EVDD0 = EVDD1 = VDD ï‚£ 5.5 V, VSS = EVSS0 = EVSS1 = 0 V)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Transfer rate - 115.2 k 1 M bps
34.5.4 LIN/UART Module (RLIN3) UART Mode
(T
A = -40 to +105ï‚°C, 2.7 V ï‚£ EVDD0 = EVDD1 = VDD ï‚£ 5.5 V, VSS = EVSS0 = EVSS1 = 0 V)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Transfer rate -
Operation mode,
HALT mode
LIN communication clock source
(f
CLK or fMX):
4 to 32 MHz
5333 kbps
SNOOZE mode
LIN communication clock source
(f
CLK):
1 to 32 MHz
FRQSEL4 = 0 in the user option
byte (000C2H/020C2H)
4.8
LIN communication clock source
(f
CLK):
1 to 32 MHz
FRQSEL4 = 1 in the user option
byte (000C2H/020C2H)
2.4

Table of Contents