RL78/F13, F14 CHAPTER 12 A/D CONVERTER
R01UH0368EJ0210 Rev.2.10 734
Dec 10, 2015
Figure 12-20. Conversion Operation of A/D Converter (Software Trigger Mode)
A/D conversion operations are performed continuously until bit 7 (ADCS) of the A/D converter mode register (ADM) is
reset (0) by software.
If a write operation is performed to the analog input channel specification register (ADS) during an A/D conversion
operation, the conversion operation is initialized, and if the ADCS bit is set (1), conversion starts again from the beginning.
Reset signal generation clears the A/D conversion result register (ADCR, ADCRH) to 0000H or 00H.
Sampling time
Sampling A/D conversion
Undefined
A/D converter
operation
ADCS 1 or ADS rewrite
SAR
ADCR
INTAD
SAR clear
Conversion time
Conversion
result
Conversion
result

Table of Contents