RL78/F13, F14 CHAPTER 15 SERIAL ARRAY UNIT
R01UH0368EJ0210 Rev.2.10 957
Dec 10, 2015
15.6.8 Procedure for processing errors that occurred during clock synchronous serial communication with SPI
function
The procedure for processing errors that occurred during clock synchronous serial communication with SPI function is
described in Figure 15-120.
Figure 15-120. Processing Procedure in Case of Overrun Error
Software Manipulation Hardware Status Remark
Reads serial data register mn (SDRmn). The BFFmn bit of the SSRmn register is
set to 0 and channel n is enabled to
receive data.
This is to prevent an overrun error if the
next reception is completed during error
processing.
Reads serial status register mn
(SSRmn).
Error type is identified and the read
value is used to clear error flag.
Writes 1 to serial flag clear trigger
register mn (SIRmn).
Error flag is cleared. Error can be cleared only during
reading, by writing the value read from
the SSRmn register to the SIRmn
register without modification.
Remark m: Unit number (m = 0, 1), n: Channel number (n = 0, 1), mn = 00, 01, 10, 11