130 Rockwell Automation Publication 750-TG101A-EN-P - June 2022
Chapter 6 Frame 7 Renewal Kits Installation
Control Pod Access Cover
Replacement
Replacement kit catalog numbers: SK-RT-AD1-F67, SK-RT-AD1-F67-XT
These kits can be used for IP00, NEMA/UL Open Type, IP21, NEMA/UL Type 1
and flange, NEMA/UL Type 4X/12 back enclosures.
Remove the Control Pod Access Cover
Follow these steps to remove the control pod access cover.
1. Review the Product Advisories
on page 11.
2. Turn off and lock-out incoming power. See Remove Power from the
System on page 12.
3. Loosen the two M3 x 6.4 mm slotted-Torx screws that secure the control
pod access cover to the drive cover and remove the access cover.
Install the Control Pod Access Cover
Install the control pod access cover in the reverse order of removal.
3
M3 x 6.4 mm
T15 or F - 6.4 mm (0.25 in.)
0.45 N
m (4.0 lbin)
=
3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley PowerFlex 755TS Series and is the answer not in the manual?

Rockwell Automation Allen-Bradley PowerFlex 755TS Series Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley PowerFlex 755TS Series
CategoryDC Drives
LanguageEnglish

Related product manuals