Specifications and Site Requirements
Electrical Specifications
166 MagneMotion
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
BACKLIGHT TIMEOUT 30 SEC – Backlight turns off 30 seconds after last button push.
1 MIN – Backlight turns off 1 minute after last button push.
1 MIN – Backlight turns off 3 minutes after last button push.
5 MIN – Backlight turns off 5 minutes after last button push.
10 MIN – Backlight turns off 10 minutes after last button push.
NEVER – Backlight is always on.
CYCLIC DATA SELECT BUS VOLT – Bus voltage is displayed in the home page
(0.0 - 600.0 V).
INV TEMP – Inverter temperature is displayed in the home page
(0.0 - 80.0 C).
MOTOR TEMP – Motor temperature is displayed in the home page
(0.0 - 80.0 C).
OUT CUR – Inverter out current is displayed in the home page
(0.0 - 20.0 A).
MAIN MENU MODULE INFO – Selects the MODULE INFO page.
MOTOR INFO – Selects the MOTOR INFO page.
DIAGNOSTICS – Selects the DIAGNOSTICS page.
MODULE INFO CATALOG NUMBER – Catalog number (24 character string max).
FW – Firmware revision (major.minor.patch format ex. 1.23.456)
HW REV – Hardware revision (2 character string).
SERIAL# – Serial number (6 character string ex. R123456).
MOTOR INFO MODEL – Configured motor model number (1 METER, HALF
METER, DUAL HALF, DOUBLE WIDE).
SERIAL# – Motor serial number (12 character string ex.
MMI161000084).
MOTOR TYPE – Actual motor type number (1 METER, HALF
METER, DUAL HALF, DOUBLE WIDE).
DIAGNOSTICS DRIVE DIAGNOSTICS – Selects the DRIVE DIAGNOSTICS page.
MOTOR DIAGNOSTICS – Selects the MOTOR DIAGNOSTICS
page.
SAFETY INPUTS – Selects the SAFETTY INPUTS page.
SAFETY DIAGNOSTICS – Selects the SAFETY DIAGNOSTICS
page.
DRIVE DIAGNOSTICS DC BUS – The DC bus voltage of currently selected inverter
(0.0 - 900.0 V).
INV TEMP – Temperature of currently selected inverter
(0.0 - 80.0 C).
Table 4-50: LCD Pages (Continued)
Menu/Submenu Information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation MagneMotion QuickStick HT and is the answer not in the manual?

Rockwell Automation MagneMotion QuickStick HT Specifications

General IconGeneral
BrandRockwell Automation
ModelMagneMotion QuickStick HT
CategoryAccessories
LanguageEnglish

Related product manuals