Tuning
9.4 Real-time auto tuning
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
321
9.4
Real-time auto tuning
With real-time auto tuning, the servo drive can automatically estimate the ratio of load
moment of inertia and set the optimum control parameters.
Pre-conditions for the real-time auto tuning
The drive must be controlled by the host controller.
The machine actual load moment of inertia is different when the machine moves to the
different positions.
Make sure that the motor has multiple accelerations and decelerations. Step command is
recommended.
Machine resonance frequency changes when the machine is running.
Real-time auto tuning procedure
Proceed as follows to perform real-time auto tuning for the SINAMICS V90 servo drive.