383
Diagnostics
11
11.1
Overview
General information about faults and alarms
The errors and states detected by the individual components of the drive system are
indicated by messages.
The messages are categorized into faults and alarms.
Properties of faults and alarms
Faults
Are identified by Fxxxxx.
Can lead to a fault reaction.
Must be acknowledged once the cause has been remedied.
Status via control unit and LED RDY.
Status via MODBUS status word PZD1.1 (fault status).
Entry in the fault buffer.
Alarms
Are identified by Axxxxx.
Have no further effect on the drive.
The alarms are automatically reset once the cause has been remedied. No
acknowledgement is required.
Status via Control Unit and LED RDY.
Entry in the alarm buffer.
General properties of faults and alarms
Triggering on selected messages possible.
Contain the component number for identifying the affected SINAMICS component.
Contain diagnostic information on the relevant message.

Table of Contents

Other manuals for Siemens SIMOTICS S-1FL6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS S-1FL6 and is the answer not in the manual?

Siemens SIMOTICS S-1FL6 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS S-1FL6
CategoryServo Drives
LanguageEnglish

Related product manuals