SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
341
Parameters
10
10.1
Overview
The section below lists all the parameters of the SINAMICS V90 servo drive.
Parameter number
Numbers prefixed with an "r" indicate that parameter is a read-only parameter.
Numbers prefixed with a "p" indicate that the parameter is an editable parameter.
Effective
This indicates the conditions for making parameterization effective. Two conditions are
possible:
IM (
Im
mediately): Parameter value becomes effective immediately after changing.
RE (
Re
set): Parameter value becomes effective after repower-on.
Can be changed
This indicates when the parameter can be changed. Two states are possible:
U
(Run): Can be changed in the "
Running
" state when the drive is in "S ON" state. The
"RDY" LED lights up green.
T
(Ready to run): Can be changed in the "
Ready
" state when the drive is in "S OFF" state.
The "RDY" LED lights up red.
Note
When judging the state of the drive according to the "RDY" LED, ensure that no faults or
alarms exist.

Table of Contents

Other manuals for Siemens SIMOTICS S-1FL6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS S-1FL6 and is the answer not in the manual?

Siemens SIMOTICS S-1FL6 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS S-1FL6
CategoryServo Drives
LanguageEnglish

Related product manuals