9.9 Battery monitoring
The installed buffer battery has a service life of at least 5 years. The status can be checked
with two-tier battery monitoring.
When the first warning level is reached, the remaining service life of the battery for buffering
CMOS data and buffered SRAM is at least 1 month.
You will find further information on the battery warning at: Two-stage battery monitoring
(Page 186)
Lithium battery - ordering data
Designation Article number Further information
Lithium battery A5E30314053 Spare part
Parameter assignment/addressing
9.9 Battery monitoring
SIMOTION P320-4 E / P320-4 S
Commissioning and Hardware Installation Manual, 11/2016 151