6.5.2 SYNC I/O connecting cable / Plugging in the IsoPROFIBUS board
To be able to plug in the IsoPROFIBUS board, the device must be opened and the SYNC I/O
connecting cable must be rerouted:
1. Remove the screws of the upper cover plate and open the SIMOTION P320-4.
At the factory, the SYNC I/O connecting cable is secured in the device using an adhesive
tape.
Figure 6-4 Opened SIMOTION P320-4 with SYNC I/O connecting cable as delivered ex works
2. Remove the adhesive tape and change the position of the SYNC I/O connecting cable as
follows:
the SYNC I/O connecting cable is routed to the interface side of the device and secured
there again.
Connection
6.5 Connecting PROFIBUS
SIMOTION P320-4 E / P320-4 S
Commissioning and Hardware Installation Manual, 11/2016 105