EasyManuals Logo

Siemens SINAMICS G120 User Manual

Siemens SINAMICS G120
732 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #484 background imageLoading...
Page #484 background image
Parameters
Connector/Binector (BICO)-Parameters
1-484
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
p20118[0...1] CI: DIV 0 inputs / DIV 0 inputs
p20123[0...1] CI: DIV 1 inputs / DIV 1 inputs
p20128 CI: AVA 0 input X / AVA 0 input X
p20133 CI: AVA 1 input X / AVA 1 input X
p20218[0...1] CI: NSW 0 inputs / NSW 0 inputs
p20223[0...1] CI: NSW 1 inputs / NSW 1 inputs
p20228 CI: LIM 0 input X / LIM 0 input X
p20236 CI: LIM 1 input X / LIM 1 input X
p20244[0...1] CI: PT1 0 inputs / PT1 0 inputs
p20250[0...1] CI: PT1 1 inputs / PT1 1 inputs
p20256[0...1] CI: INT 0 inputs / INT 0 inputs
p20266 CI: LVM 0 input X / LVM 0 input X
p20275 CI: LVM 1 input X / LVM 1 input X
p20284 CI: DIF 0 input X / DIF 0 input X
p20308[0...3] CI: ADD 2 inputs / ADD 2 inputs
p20312[0...1] CI: NCM 0 inputs / NCM 0 inputs
p20318[0...1] CI: NCM 1 inputs / NCM 1 inputs
p20372 CI: PLI 0 input X / PLI 0 input X
p20378 CI: PLI 1 input X / PLI 1 input X
p31023[0...3] CI: Multi-zone control setpoint input / Zone_ctrl setp inp
p31026[0...2] CI: Multi-zone control actual-value input / Zon_ctrl act inp
1.4.3 Binector Output Parameters
Product: SINAMICS G120, Version: 4402100, Language: eng, Type: BO
r0751.0...10 BO: CU analog inputs status word / CU AI status word
r0785.0...1 BO: CU analog outputs status word / CU AO ZSW
r0807.0 BO: Master control active / PcCtrl active
r1025.0 BO: Fixed speed setpoint status / n_setp_fix status
r2043.0...2 BO: PROFIdrive PZD state / PD PZD state
r2090.0...15 BO: PROFIdrive PZD1 receive bit-serial / PZD1 recv bitw
r2091.0...15 BO: PROFIdrive PZD2 receive bit-serial / PZD2 recv bitw
r2092.0...15 BO: PROFIdrive PZD3 receive bit-serial / PZD3 recv bitw
r2093.0...15 BO: PROFIdrive PZD4 receive bit-serial / PZD4 recv bitw
r2094.0...15 BO: Connector-binector converter binector output / Con/bin outp
r2095.0...15 BO: Connector-binector converter binector output / Con/bin outp
r8413.0...1 BO: RTC DTC1 output / RTC DTC1 output
r8423.0...1 BO: RTC DTC2 output / RTC DTC2 output
r8433.0...1 BO: RTC DTC3 output / RTC DTC3 output
r9935.0 BO: POWER ON delay signal / POWER ON t_delay
r20031 BO: AND 0 output Q / AND 0 output Q
r20035 BO: AND 1 output Q / AND 1 output Q
r20039 BO: AND 2 output Q / AND 2 output Q
r20043 BO: AND 3 output Q / AND 3 output Q
r20047 BO: OR 0 output Q / OR 0 output Q
r20051 BO: OR 1 output Q / OR 1 output Q
r20055 BO: OR 2 output Q / OR 2 output Q
r20059 BO: OR 3 output Q / OR 3 output Q
r20063 BO: XOR 0 output Q / XOR 0 output Q
r20067 BO: XOR 1 output Q / XOR 1 output Q
r20071 BO: XOR 2 output Q / XOR 2 output Q
r20075 BO: XOR 3 output Q / XOR 3 output Q

Table of Contents

Other manuals for Siemens SINAMICS G120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120 and is the answer not in the manual?

Siemens SINAMICS G120 Specifications

General IconGeneral
Power Range0.37 kW to 250 kW
Output Voltage0 V to Input Voltage
Frequency Range0 Hz to 650 Hz
Enclosure RatingIP20, IP21, IP55
Control ModesV/f control, vector control, servo control
Protection FeaturesOvervoltage, undervoltage, short circuit
Communication InterfacesPROFIBUS, PROFINET, Modbus RTU
Operating Temperature-10°C to +50°C
Cooling MethodAir cooling
Input Voltage200 V to 240 V, 380 V to 480 V, 500 V to 690 V