EasyManuals Logo

Siemens SINAMICS G120 User Manual

Siemens SINAMICS G120
732 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #643 background imageLoading...
Page #643 background image
Signals and monitoring functions
Function diagrams
2-643
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Fig. 2-130 8020 – Monitoring functions 1
- 8020 -
Function diagram
87654321
FP_8020_97_51.vsd
Signals and monitoring functions
G120 CU230P-2
13.12.2010 V4.4
Monitoring functions 1
T0
0
1
[8010.2]
+
[3050.8]
1
0
T0
1
1
0
[6730.1]
[6731.1]
[6732.1]
1
0
[6714.8]
0
1
0T
0T
0T
[6730.4]
[6731.4]
[6732.4]
0
1
0
T0
1
0
0
0
1
n_min
p1080
ZSW monitor 1
r2197
r2197
.0
n_hysteresis 3
p2150
r2169
n_act smth message [1/min]
r1119
RFG setp at inp [1/min]
r0063
n_act [1/min]
r0070
Vdc act val [V]
r0068
I_act abs val [Aeff]
r0072
U_output [Veff]
n_hysteresis 3
p2150
n_standst n_thresh
p1226
Pulse suppr t_del
p1228
Vdc thresh val
p2172
Vdc comp t_del
p2173
Vdc comp t_del
p2173
I_thresh rch t_del
p2171
I_thres
p2170
I_thres
p2170
I_thresh rch t_del
p2171
Outp_ld iden I_lim
p2179
t_del no load
p2180
ZSW 2
r0053
r0053
.2
[2511.6]
ZSW monitor 1
r2197
r2197
.4
ZSW 2
r0053
r0053
.6
[2511.6]
ZSW monitor 1
r2197
r2197
.5
ZSW 2
r0053
r0053
.1
[2511.6]
ZSW monitor 1
r2197
r2197
.9
ZSW 2
r0053
r0053
.7
[2511.6]
ZSW monitor 1
r2197
r2197
.10
ZSW 2
r0053
r0053
.8
[2511.6]
ZSW monitor 1
r2197
r2197
.8
ZSW 2
r0053
r0053
.3
[2511.6]
ZSW monitor 2
r2198
r2198
.8
ZSW monitor 1
r2197
r2197
.11
Enable Pulses
|n_act| <= p1080
|n_act| >= n_set
|n_act| <= n_standst
Vdc_act <= p2172
Vdc_act > p2172
I_act >= p2170
I_act < p2170
Output load present
Drive: No motor detected
A07929
-1
1
0
[0]
1
M_act_filt T
0 ... 1000000 [ms]
p3233 [D] (100)
1

Table of Contents

Other manuals for Siemens SINAMICS G120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120 and is the answer not in the manual?

Siemens SINAMICS G120 Specifications

General IconGeneral
Power Range0.37 kW to 250 kW
Output Voltage0 V to Input Voltage
Frequency Range0 Hz to 650 Hz
Enclosure RatingIP20, IP21, IP55
Control ModesV/f control, vector control, servo control
Protection FeaturesOvervoltage, undervoltage, short circuit
Communication InterfacesPROFIBUS, PROFINET, Modbus RTU
Operating Temperature-10°C to +50°C
Cooling MethodAir cooling
Input Voltage200 V to 240 V, 380 V to 480 V, 500 V to 690 V

Related product manuals