EasyManuals Logo

Siemens SINAMICS G120 User Manual

Siemens SINAMICS G120
732 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #615 background imageLoading...
Page #615 background image
Free Function Blocks
Function diagrams
2-615
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Fig. 2-105 7234 – PST (pulse extender)
- 7234 -
Function diagram
87654321
FP_7234_97_51.vsd
Time function blocks
G120 CU230P-2
13.12.2010 V4.4
PST (pulse extender)
PST 1
PST 0
Q
T
PST 0 RTG
5 ... 9999
p20181 (9999)
PST 0 pulse_dur ms
0.00 ... 60000.00
p20179 (0.00)
PST 0 RunSeq
0 ... 7999
p20182 (490)
PST 0 output Q
r20180
T
I
R
[0]
PST 0 inputs
p20178
[1]
Input pulse
Reset input
Q
T
PST 1 RTG
5 ... 9999
p20186 (9999)
PST 1 pulse_dur ms
0.00 ... 60000.00
p20184 (0.00)
PST 1 RunSeq
0 ... 7999
p20187 (500)
PST 1 output Q
r20185
T
I
R
[0]
PST 1 inputs
p20183
[1]
Input pulse
Reset input

Table of Contents

Other manuals for Siemens SINAMICS G120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120 and is the answer not in the manual?

Siemens SINAMICS G120 Specifications

General IconGeneral
Power Range0.37 kW to 250 kW
Output Voltage0 V to Input Voltage
Frequency Range0 Hz to 650 Hz
Enclosure RatingIP20, IP21, IP55
Control ModesV/f control, vector control, servo control
Protection FeaturesOvervoltage, undervoltage, short circuit
Communication InterfacesPROFIBUS, PROFINET, Modbus RTU
Operating Temperature-10°C to +50°C
Cooling MethodAir cooling
Input Voltage200 V to 240 V, 380 V to 480 V, 500 V to 690 V