Parameters
Connector/Binector (BICO)-Parameters
1-486
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
r20341 BO: PDE 3 output Q / PDE 3 output Q
r20346 BO: PDF 2 output Q / PDF 2 output Q
r20351 BO: PDF 3 output Q / PDF 3 output Q
r20356 BO: MFP 2 output Q / MFP 2 output Q
r20361 BO: MFP 3 output Q / MFP 3 output Q
1.4.4 Connector Output Parameters
Product: SINAMICS G120, Version: 4402100, Language: eng, Type: CO
r0021 CO: Actual speed smoothed / n_act smooth
r0025 CO: Output voltage smoothed / U_outp smooth
r0026 CO: DC link voltage smoothed / Vdc smooth
r0027 CO: Absolute actual current smoothed / I_act abs val smth
r0032 CO: Active power actual value smoothed / P_actv_act smth
r0034 CO: Motor utilization / Motor utilization
r0035 CO: Motor temperature / Mot temp
r0036 CO: Power unit overload I2t / PU overload I2t
r0037[0...19] CO: Power unit temperatures / PU temperatures
r0060 CO: Speed setpoint before the setpoint filter / n_set before filt.
r0062 CO: Speed setpoint after the filter / n_set after filter
r0063[0...2] CO: Speed actual value / n_act
r0064 CO: Speed controller system deviation / n_ctrl system dev
r0066 CO: Output frequency / f_outp
r0067 CO: Output current, maximum / I_outp max
r0068[0...1] CO: Absolute current actual value / I_act abs val
r0069[0...6] CO: Phase current actual value / I_phase act value
r0070 CO: Actual DC link voltage / Vdc act val
r0072 CO: Output voltage / U_output
r0074 CO: Modulat_depth / Modulat_depth
r0075 CO: Current setpoint field-generating / Id_set
r0076 CO: Current actual value field-generating / Id_act
r0077 CO: Current setpoint torque-generating / Iq_set
r0078 CO: Current actual value torque-generating / Iq_act
r0079 CO: Torque setpoint / M_set total
r0080[0...1] CO: Torque actual value / M_act
r0081 CO: Torque utilization / M_Utilization
r0082[0...2] CO: Active power actual value / P_act
r0083 CO: Flux setpoint / Flex setp
r0084[0...1] CO: Flux actual value / Flux act val
r0087 CO: Actual power factor / Cos phi act
r0094 CO: Transformation angle / Transformat_angle
r0289 CO: Maximum power unit output current / PU I_outp max
r0752[0...3] CO: CU analog inputs input voltage/current actual / CU AI U/I_inp act
r0755[0...3] CO: CU analog inputs actual value in percent / CU AI value in %
r0944 CO: Counter for fault buffer changes / Fault buff change
p1001[0...n] CO: Fixed speed setpoint 1 / n_set_fixed 1
p1002[0...n] CO: Fixed speed setpoint 2 / n_set_fixed 2
p1003[0...n] CO: Fixed speed setpoint 3 / n_set_fixed 3
p1004[0...n] CO: Fixed speed setpoint 4 / n_set_fixed 4
p1005[0...n] CO: Fixed speed setpoint 5 / n_set_fixed 5
p1006[0...n] CO: Fixed speed setpoint 6 / n_set_fixed 6
p1007[0...n] CO: Fixed speed setpoint 7 / n_set_fixed 7
p1008[0...n] CO: Fixed speed setpoint 8 / n_set_fixed 8

Table of Contents

Other manuals for Siemens SINAMICS G120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120 and is the answer not in the manual?

Siemens SINAMICS G120 Specifications

General IconGeneral
Power Range0.37 kW to 250 kW
Output Voltage0 V to Input Voltage
Frequency Range0 Hz to 650 Hz
Enclosure RatingIP20, IP21, IP55
Control ModesV/f control, vector control, servo control
Protection FeaturesOvervoltage, undervoltage, short circuit
Communication InterfacesPROFIBUS, PROFINET, Modbus RTU
Operating Temperature-10°C to +50°C
Cooling MethodAir cooling
Input Voltage200 V to 240 V, 380 V to 480 V, 500 V to 690 V