Mechanical Mounting
Respect all local standards and requirements during mechanical installation.
4.1 Installation Location Selection
Selecting an optimal installation location for the Logger1000 is critical to safe operation, long
service life, and sound performance.
Take the following requirements into account when selecting the installation location:
With the ingress of protection IP20, the Logger1000 can be installed only indoors.
Ambient temperature range: -30°C to +60°C.
The relative humidity should not exceed 95%. If otherwise, the internal components will
be damaged.
Take anti-moisture and anti-corrosion measures.
Ensure that enough space is reserved around the Logger1000. The installation location
should be 1,500mm above the ground surface, and maintenance clearance of at least
500mm should be reserved. Minimum clearances are shown in the figure below.
When there are external devices (such as Meteo Station) connected to the Log-
ger1000, users should add corresponding communication SPD according to onsite
condition.

Table of Contents

Other manuals for Sungrow Logger1000B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow Logger1000B and is the answer not in the manual?

Sungrow Logger1000B Specifications

General IconGeneral
BrandSungrow
ModelLogger1000B
CategoryData Loggers
LanguageEnglish

Related product manuals