Module installation and removal
Module installation and removal
The following procedures describe how to install and remove generator, genlock,
and GPS modules from the TG8000 mainframe. A screwdriver w ith a #1 Phillips
tip is the onl
y t ool you need to install or remove a module.
CAUTION. Electrostatic discharge (ESD) can damage components on the module
and mainframe. To prevent ESD or other component damage, follow the service
preparation guidelines when installing, removing or handling a module. (See
page 1-4, Service preparation.)
To make module removal easier, attach terminations or BNC cables to the module
connectors. The connectors may be damaged if too much force is applied during
module removal.
1–10 TG8000 Multiformat Test Signal Generator Service Manual

Table of Contents